Distilled water machine manuals

DISTILLED WATER MACHINE MANUALS 2 THE HAMILTON TIMES

I. INSTALLATION

  • Distilled water machine must be installed near the water source place convenient for the installation of exhaust and cooling water supply pipes.
  • The machine must be installed in cool by the other devices because of the process of steam operation in air can be blown out to affect surrounding equipment. Insert the cable television network
  • The machine must be connected to the power source through the Aptomat to protect the machine when there are electrical problems.
  • Large capacity machines(full air consumption approx. 6kW) When installing the mounting attention to wire large enough (larger wire size 3.5) to ensure safety against heat and damage to the wire when running continuously for hours.
  • Water line mounted on must have water flow adjustment valve.
  • Sugar water to the must to flow because the air pump does not come

II,OPERATION

  • Connect the power source,at this time 2 the green light on the control panel light,air power has.
  • Screw the tap water cooling supply sufficient flow note adjust the water flow and water level in the water supply pipe to the times 1 awash with red line.
  • When water flooded the burning stick in times 1 then switch on the dashboard yellow light times 1 light.
  • When there have been distilled times 1 flows to the average burn 2 submerged combustion bar then the switch times 2 on the dashboard yellow light times 2 will light.
  • During operation there are at the steam blown out the Chamber air proves insufficient cooling water flow, need larger cooling valve open.
  • The machine will disconnect when losing coolant but not so that the subjective,the need for the water supply line flow.
  • The average distilled times 2 only disconnect when there is no water in the vase ,not turn power switch time 2 When there is not enough water in the average burn 2.
  • The average burning time 2 only works when the average burning time 1 operation

III. MAINTENANCE.

  • After running for some time in the average burning time 1 There was a real pile phenomenon Ca needs to contact an eyewash monthly by pouring lemon Acid (C6H8O7) in the jar and soak in 12 remove the drain valve basics will flow out .
  • When too much dirt needs to remove must be the average burn times 1 out and wash.
  • Note When the dirt lot not exposed wash will lead to low water take performance and can cause burning stick fracture.