About Keli electronic bench-XK3188T1
Keli electronic bench-XK3188T1 is the product of Keli-China, integrated the features bring efficiency and accuracy, used in trade, the manufacturing industry. Bench electronics XK3188T1-D use the chip switch 2-AAD with processor speed, quick response, accuracy. The early show with the plastic casing sure design, can rotate 360 speed, frame: stainless steel corrosion, new designed weight structure, weight has many power supplies with AC voltage switch, DC adapter fit.
Essential characteristics of electronic desk kếcân Keli XK3118T1
- Electronic bench XK3188T1 is certified to OIML R76 standard fit and CE.
- A/D conversion accuracy, the ability to read 1/30000. The Power on mode(turn on the source) , Auto zero-set range( Auto range Setup 0), Manual zero-set range ( manually setting the Strip 0) are set separately.
- The early show is random charging low power and stable electrical protective devices.
- LCD display large size with 5 soft function keys for easy operation, Red digit provides the best visibility in all light conditions.
- Circuit design with dynamic loading may extend the life of the battery, battery saving mode function turn off automatically power off when not in use.
- Weighing is made from solid stainless steel, resistant to chemical corrosion brings stability and accuracy in long time
- Loadcell aluminum material is designed according to international standard provides the ability to determine the weight of the sample material 1 the way most.
Offer includes: Primary balance, adapter, Manual
See more products by Vietnam innotec bench import and distribution in: Electronic desk weight
Guidance connect with load circuit (loadcell) bench electronics XK3118T1 Keli
Specify |
||
(1) |
Pulse source (-) |
|
(2) |
Feedback (-) |
|
(5) |
Anti-interference |
|
(6) |
Pulse source(+) |
|
(7) |
Feedback (+) |
|
(8) |
Signal (-) |
|
(9) |
Signal (-) |
♦ Note:
- Connect off the foot 1 and 2, the foot 6 and 7 When the connection with the Loadcell only 4 the wire.
- The connection between loadcell and early show weight must be guaranteed, exactly; cool Shield wire must be earthed. Do not connect or disconnect the loadcell when the weight is on, This can damage the head weight
- The early show weight and loadcell is the very sensitive equipment, so make sure to avoid lightning, avoid connecting to power while welding, the activity causing the other power supply of the ... and loadcell.
Tv Portal |
||
(1) |
RXD |
|
(2) |
TXD |
|
(3) |
GND |
|
(4) |
The loop on the screen show the |
|
(5) |
Current loop output show |
The legs of 4 (in put) Black wire, the number of 5 (out put) Red wire