máy đo BOD AL606

BOD meter AL606

Model: AL606

Manufacturer: Aqualytic

That– biochemical oxygen demand- is characteristic for the number for the amount of oxygen required for the micro-organisms decompose organic substances in wastewater. BOD meter AL606 the key is determining the amount of organic matter can decompose in water.

Reference a number of gauges That in the category: BOD meters

Order

Why shopping at INNOTEC?

  1. Get every day.
  2. View restaurant > Satisfaction > Payments
  3. Be paid under the policy change preferences
  4. Guarantee 12 month, support 24/24

SKU: AL606 Category:

That-biochemical oxygen demand

That– biochemical oxygen demand- is characteristic for the number for the amount of oxygen required for the micro-organisms decompose organic substances in wastewater. Measure That the key is determining the amount of organic matter can decompose in water. The differences between That and the chemical oxygen demand (COD) is the index COD is determined by the amount of organic substances can not biodegradable and organic substances can decompose.

That calculate the result by considering the influence of waste water of household and industrial zones on the plant and the trench.


Highlights of the BOD meter AL606

  • Choose the form directly.
  • Direct and accurate display with value mg/l
  • Easy manual operation.
  • Save all measured values.
  • Sources used 110-240 V/50-60 Hz
  • Calculating range from 0-40 mg/l to 0-4000 mg/l That.
  • Automatically start the calculation function after the temperature is balanced.
  • High safety, environmental coal.
  • Pendulum system with the ability to self-.
  • Communication RS 232

The accuracy of the AL606 BOD

Sensor system AL606 BOD of Aqualytic ® allows measurements on 6 sample and is based on the principle of the barometer. Measuring machine That will calculate the amount of oxygen pressure change by considering the amount of consumption of oxygen stored in the volume does not change.

The application of measuring meter BOD AL606

  • Measure WW
  • Determination of biological activity
  • Of waste water treatment plant.
  • Analysis in the laboratory
  • Science research.

Measuring rule of BOD meter AL606

Provides a way to measure the exact amount of oxygen directly consumed by microorganisms from the air or in a closed condition of constant temperature and the impact. CO2 was born in the process of metabolism of bacteria is a chemical reaction with KOH traps contained in Bangkok in peace.

The result is that the pressure in the system decreases, that this is proportional to the value That measured by the sensor That.Mức That then be made directly units mg/l, the results are stored in memory and can be exported to the display at any time. Measurement time can be user to choose from 1 to 28 on line with measuring applications . While short-time measurement is useful for scientific applications, standard measurements usually lasts around 5 day.

may-do-BOD-AL606


BOD meter AL606 DDmeasurable outcomes assessments

If the measuring cycle is 24 h, then AL606 That will record the results after every hour. With the measuring cycle is 48 now measuring machine AL606 That be saved after each 2 now. If the cycle from 3-28 day, the values will be saved after every day. All the values can be called out to anyone at any time.

Auto start function

If the measurement That taking place in the temperature 20theC then AL606 That will measuring the temperature of the sample and lets just start when the temperature of the sample as in the algorithms stored in the controller.

Measuring system of measuring machine That AL606 includes sample vessels, measuring sensor,stirring system ,spill resistant,nitrate reagents inhibit and KOH do extra absorbent.

may-do-BOD-AL606


Measurement range and volume of specimens measuring BOD AL606

The level of the model That Depending on the nature of the organic material, can change the volume of the sample. The system calculates measuring machine That AL606 as a result of the calibration on the change of the specimen and measuring the wage system in the table below (are displayed as mg/l)

The scope BOD mg/l

Sample capacity ml

0 – 40

428

0 – 80

360

0 – 200

244

0 – 400

157

0 – 800

94

0 – 2000

56

0 – 4000

21.7

 

View more : Air stirring from his heat

Can interest you : electronic analytical balance

There are no reviews yet.

Be the first to review "the measurement of BOD AL606”

Measuring principle

Barometer,contains no mercury,electronic pressure sensor

Measurement range (mg/l an2)

0 – 40, 0 – 80, 0 – 200,0 – 400, 0 – 800,

0 – 2000, 0 – 4000 mg/l

The precision

0.5% the entire area of the measurement in 20theC

Application

That5, That7, OECD 301 F ..

Results show

That [mg/l]; 4 -the number of ; 7 – segment LED

Show calculation features

BOD-scope, the volume, time of measurement.

 

Measuring cycle

Choose users from 1-28 day.

Automatically save results

Up to 28 results, Depending on the measurement time

Save results

Each hour ( the cycle is 1 day)

Each 2 now ( the cycle is 2 day)

Every day (the cycle is 3-28 day)

Automatically started

After the temperature balance of the sample.

You can use the switch.

Regulatory resources

3 pin alkaline-manganese

 

Communicate

RS 232 connect to the printer and PC

The clock

Real time

Class of protection

IP54

Size (LxWxH)

375 x 195 x 230 mm

The weight

3850g,

5750g contains the comments template.

Covers

ABS

Contact Me on Zalo