U-51
|
U-52
|
U-52G
|
U-53
|
U-53G
|
Sensor head
|
Temperature measurement
|
-10the to 50theC
|
The diameter
|
96 mm
|
Length
|
340 mm
|
Cable length
|
Standard: 2 m ,options:10m
|
Self editing
|
.
|
.
|
.
|
The measurement of turbidity
|
_
|
_
|
.
|
The depth allows
|
30 m
|
The material in contact with the solution
|
PPS, glass, SUS316L, SUS304, FKM, PEEK, Q,Titaniumu, FEP membrane, POM
|
Weight
|
1800 g
|
Water resistant
|
JIS protection level 8
|
Signal processor
|
External size
|
115(In) X 66(D) X 283(H) mm
|
Weight
|
800g (1.76 lbs)
|
LCD
|
320 x240 liquid-crystal display
|
Memory
|
1000
|
Information
|
USB
|
Pin
|
4x Pin C
|
Battery
|
70 now
|
500 measurements
|
Water resistant
|
JIS protection level 7
|
The storage temperature
|
-10theC to 60theC
|
The surrounding temperature
|
-5theC to 45theC
|
pH
-Calibration 2 the point
-Thermally stable self
|
Measuring principle
|
Cell separation method
|
The scope
|
pH0 to 14
|
The precision
|
0.01 pH
|
Repeat mode
|
±0.05pH
|
The deviation
|
±0.1pH
|
Oxidation Reduction Potential(ORP)
|
Measuring principle
|
Platinum electrode method
|
The scope
|
-2000 mV to +2000 mV
|
The precision
|
1 mV
|
Repeat mode
|
±5 mV
|
The deviation
|
±15 mV
|
Dissolved Oxygen (DO)
|
Measuring principle
|
Polarographic method
|
The scope
|
0 to 50.0 mg/L
|
The precision
|
0.01 mg/L
|
Repeat mode
|
±0.1 mg/L
|
The deviation
|
0 to 20 mg/L: ±0.2 mg/L 20 to 50 mg/L:±0.5 mg/L
|
Conductivity (COND)
|
Measuring principle
|
4 AC electrode method
|
The scope
|
0 to 10 S/m (0 to 100 mS/cm)
|
The precision
|
0.000 to 0.999 mS/cm:0.001,1.00 to 9.99 mS/cm: 0.01,10.0 to 99.9 mS/cm: 0.1 0.0 to 99.9 mS/m: 0.1,0.100 to 0.999 S/m: 0.001,1.00 to 9.99 S/m: 0.01
|
Repeat mode
|
±0.05% F.S.
|
The deviation
|
*±1% F.S.
|
Salinity
|
Measuring principle
|
Conductivity conversion
|
The scope
|
0 to 70 PPT (permillage)
|
The precision
|
0.1 PPt
|
Repeat mode
|
±1 PPT
|
The deviation
|
±3 PPT
|
Total Dissolved Solid (TDS)
|
Measuring principle
|
Conductivity conversion
|
The scope
|
0 to 100 g/L
|
The precision
|
0.1% F.S.
|
Repeat mode
|
±2 g/L
|
The deviation
|
±5 g/L
|
Seawater specific gravity
|
Measuring principle
|
Conductivity conversion
|
The scope
|
0 to 50 δt
|
The precision
|
0.1 δt
|
Repeat mode
|
±2 δt
|
The deviation
|
±5 δt
|
Temperature
|
Measuring principle
|
Thermistor method
|
The scope
|
-10 to 55°C
|
The precision
|
0.01°C
|
Repeat mode
|
*±0.10°C (at calibration point)
|
The deviation
|
JIS class B platinum thermometer sensor (±0.3 0.005 |t|)
|
Turbidity (TURB)
|
Measuring principle
|
_
|
LED light source and 30° scattering method
|
Tungsten lamp source and 90° scattering method
|
The scope
|
0-800 NTU
|
0-1000 NTU
|
The precision
|
0.1 NTU
|
0.01NTU
|
Repeat mode
|
±5% (reading) or ±0.5 NTU whichever is greater
|
±3% (reading) or ±0.1 NTU whichever is greater
|
The deviation
|
±5% (reading) or ±1 NTU whichever is greater
|
0 to 10 NTU: ±0.5 10 to 1000 NTU: 3% (reading) or ±1 NTU whichever is greater
|
Water depth
|
Measuring principle
|
_
|
_
|
The method is based on the pressure
|
The scope
|
0 to 30 m
|
The precision
|
0.05 m
|
Repeat mode
|
±1% F.S.
|
The deviation
|
±0.3 m
|
GPS
|
12 parallel channel
|
_
|
_
|
·
|
_
|
·
|
There are no reviews yet.