Principle of germination in germination Sunshine S124

tủ-nảy-mầm-sunshine-S114

  1. The concept of the germination of seeds.

The seed's germination is defined simply as the development of the embryo in the seed that led to the formation of the seedlings.

  1. Conditions affecting the germination

To grow into seedlings, the seeds are dependent on factors from inside and outside as: moisture, temperature , oxygen, light and darkness.

  • Moisture (water): is an indispensable factor to help restore seeds and began to break the crust wrapped beads.
  • Oxygen: function helps the respiratory tree to the metabolism and stimulate the sprouting leaves.
  • Temperature: affect the development process of the cell, impact on development time of seed
  • Light and darkness: activation of the environment for the germination and it is a form of tree physiology student potential.

Because of the environmental conditions for each type of seed is different, so to be able to test, then one must create the environmental conditions in small scale to calculate the percent germination.

A germination cabinet door S124 of sunshine is designed to create environmental conditions vary accordingly to each NUTS level to germinate seed batches for.

Cabinets-bouncing-software-sunshine-S-124
Cabinets-bouncing-sprouts-sunshine-S-124

Advantages of Sunshine S124 germination cabinets

Tủ nảy mầm Sunshine S124 be equipped with real time controller with growth conditions described as outside with the separate section as:

  • Sources of moisture generated from the hot heat stabilizer underneath with a temperature of about 30-35 degrees C.
  • The oxygen source is used from outside provided in through ventilation .
  • The source of the light from the bulb was calculated to simulate true natural light source based on the capacity of the spotlights in the different time.
  • The temperature inside the control cabinet exactly by the controller has a heat sensor inside the environment should have the desired temperature, as when installed.
  • Double door structure consists of a metal shell that surrounds and a layer of glass the transparent plexiglas and very durable so users can track the growth process of seed which does not affect the temperature inside cabinets.
  • Thick cushioning layer around of which can keep the temperature inside the Cabinet are not lost escape, influence model.
  • Cabinets are a window of S124 germination with precise control of the temperature and luminosity of the cabinets.
  • LCD screen show details support the user in the installation process and tracking.
  • The recorded data can support with memory of up to 1000 test post. And can extract out the computer.
  • Cabinets can give a light cycle and different temperatures suit model nuts.

With regard to the scale of the experiment in the lab, the simulation of growth conditions in germination S124 help us to accurately calculate the germination without wasting too much time , the human costs and .

We have the recipe :

The rate of germination(%)=(The number of mature seeds sown seeds/total) x 100%

Based on the above formula, we will calculate the rate of germination in the optimal environment for.

The warning time circuits of S124 germination cabinets

Warning circuit is installed in the S124 germination cabinets to test the program and control at all time. And make sure that programs and to control the correct operation. Any surge in the power supply could cause any of the controls (temperature, humidity, and the light) to key in a location. This monitoring schedule prevent that and make sure that the operation of the machine.

View more types of laboratory equipment in the agricultural industry: Thiết bị thí nghiệm hạt

 

  1. 4 out of 5

    :

    Arictles like this just make me want to visit your website even more.

Add a review

Parameters

Single chamber S-124

Double chamber S-124D

one (burners and cooling)

Two(burners and cooling)

The volume

283 liter

283 liter

Dimensions of cabinets

555(In)x910(H)x605(D) mm

555(In)x910(H)x605(D) mm

The touch screen display

Màn LCD 2*16 characters and numbers

Màn LCD 2*16 characters and numbers

Lighting levels

OFF,25%,50%,75% and 100%

OFF,25%,50%,75% and 100%

The number of the tray

10

20

Humidity

95%

95%

The alarm

Audio/display temperature and time.

Audio/display temperature and time.

Inside cabinets

Stainless steel

Stainless steel

Temperature

Use PID from 5-50theC ±1theC

Use PID from 5-50theC ±1theC

Volatile ensemble

Finely tuned pipe

Finely tuned pipe

Controls

Used microcontroller displays temperature and humidity

Used microcontroller displays temperature and humidity

Regulatory resources

220 V50Hz,AC

220 V50Hz,AC

Time

Automatically

Automatically

Contact Me on Zalo